Serial/RS-232
The router CPU card has two RS-232 serial ports. One is for the Linux command line interface (labeled
CONSOLE), and the other is for the router's ASCII command interface (labeled RS232). If a back-up
CPU is installed, then its Linux console port is active. However, only the 'RS232' port on the active CPU
will function. The active CPU is the one with the FAULT LED turned off.
Linux Command Console (Console)
Baud Rate: 115200
Data Bits: 8
Parity: none
Stop Bits: 1
Flow Control: none
DB9 DCE
A straight (NOT a null-modem) cable is needed to connect to a PC.
ASCII API (RS232)
Baud Rate: 9600
Data Bits: 8
Parity: none
Stop Bits: 1
Flow Control: XON/XOFF (Software)
DB9 DCE
A straight (NOT a null-modem) cable is needed to connect to a PC.