The default communication parameters for the server Ports are:
9600 baud
8 data bits
No parity
1 stop bit
Xon/Xoff flow control
DCE Port type
Each Port can be individually configured for baud rates of 300-115K for specified data
parameters and as DTE or DCE types.
!
Note: Ports may also be individually disabled if desired.
3.2.5.1 Automated Port Configuration Tests
A script named pm is available to test the device ports and report the correct DTE/DCE
setting for each port. A man
page exists for pm. This can be used to troubleshoot SCS to
server connections. Hardware signals from the server are tested but Baud rates are not.
3.2.5.2 Port Adapters
You may need to adapt the cable connection for your server device. Thinklogical
®
offers serial-
to-RJ45 adapters for serial ports, both DB9 and DB25, for many common network-equipment
product applications. See Appendix F on page 85 for more information.
3.2.5.3 Serial Port Pin-out
Serial Port pin-out